WSCAD SUITE Release Notes

SUITE X PLUS Service Packs

v6.6.2.12

Release Date: 2022-05-09

SUITE X PLUS SP2

The WSCAD SUITE X PLUS SP2 offers many new features and improvements. These are listed on this page and linked to the relevant topics when possible.

Note: The updates described here depend on the discipline and upgrade level!

General
Explorer & Editors
Managers & Browsers
Import & export
Part management
Interfaces
BA module (Building Automation)
EI module (Electrical Installation)
CE module (Cabinet Engineering)

General

  • The performance when creating and editing terminal strips with many terminals (>50) has been improved.
  • Color background and text alignment of BMK fields with structure identifier are displayed correctly, even during and after moving.
  • If the size of a structure area is changed, the STKZ is correctly set to the position defined in the settings.
  • When copying a coil, the contacts of the old coil are correctly not transferred to the new coil.
  • If you assign a part to an already placed coil and make the part and the manufacturer visible, the texts are displayed on the coil and the two settings remain activated.
  • When creating the multiline name of a project group (e.g. New\aProject\aGroup), the name is displayed without the separators \a in the Project Explorer.
  • If a network path is specified in the WSCAD settings for the backup, the path will be correctly taken over when creating the project backup, also including the two required backslashes at the beginning of the path.
  • Docked windows that are displayed on a second screen in full screen mode (e.g. the preview window) remain in full screen mode after a restart of the WSCAD software.
  • When moving one or more WSCAD windows to a second monitor, the content of the windows will be displayed correctly there, even if the WSCAD software has been restarted.
  • When copying text containers, the alignment of the texts is taken over correctly.

Explorer & Editors

  • When adding a channel group to a newly created PLC parent element in the Symbol Editor, selecting a template for the channel group is possible without errors.

Managers & Browsers

  • After rebuilding the central database, the Cable Manager correctly displays the wires of cables with cable duplicates.
  • If you first define a sequence for distributed terminals in the Browser of the Terminal Manager and then convert the distributed terminals to multi-level terminals, the previously defined sequence of terminals is still displayed but is no longer taken into account.
  • If all pages on which contactor contacts have been placed are deleted, these contacts are again displayed as free in the Contactor Manager.
  • If terminals are placed via the Terminal Manager, existing structure identifiers are correctly adopted.

Import & export

  • The import of WMF files works correctly via Insert | Graphic | Image.
  • If a line width factor is specified during PDF export, dashed lines will be displayed correctly in the PDF file.
  • After changing the project language, when exporting to PDF with the Output with symbol parameters check box activated, the symbol parameters displayed in the popups are also correctly displayed in the selected project language.
  • When exporting to DXF/DWG, the older AutoCad versions R13, R14 and R15 are no longer supported, due to problems with displaying colors.

Part management

  • For contactor parts, the contact comb can be changed correctly in the Part Management via the Edit/expand contactor dialog.
  • In the Combi element dialog, you can use the + and – keys to increase or decrease the number of the additional part if a cell of the additional part is selected. If the cursor is placed directly in the Part field, the + and – characters can be entered there as text. In both cases it does not matter whether + and – are used from the letter block or from the number block of the keyboard.
  • Part data from connection attributes are correctly displayed in the reports at the associated connections.
  • If you create a new part via the part management, the current date is automatically entered in the WSCAD field Creation date in the following form: YYYY-MM-DD HH:MM
  • Importing parts into a newly created SQL part database works fine.
  • If you filter for parts in a SQL part database and then select and delete the filtered parts with CTRL+A, only these parts are deleted.

Interfaces

  • During Phoenix PROJECT complete marking export, the aspects defined as output fields are exported correctly. In addition all output fields that were taken over from the „Cable chart” placeholder list are exported correctly.
  • Phoenix PROJECT complete planning import and export of terminal strips and DIN rails has been improved. Terminal strip ref. names, terminal accessories, levels and terminal position numbers (KPN) of multilevel terminals, wire jumpers and plug-in jumpers as well as height, width and depth of the elements on a DIN rail are output and imported correctly.
  • Via Interfaces | Production | Steinhauer PWA, all rotated elements are output correctly.

BA module (Building Automation)

  • If the function text of a symbol is changed in the Data Point Browser, the function text is also changed in all other disciplines.
  • When inserting a symbol into the plan via the Material Explorer, the data points of the symbol are displayed correctly in Data Point Browser.
  • When linking an EE symbol to a BA symbol via the BMK in the Enter reference designation dialog, the data points of the BA symbol are displayed correctly in the EE symbol via the Data Point Browser.
  • In the Plugin Manager, only one datapoint key plugin can be activated at a time, not several at once.

EI module (Electrical Installation)

  • Risers can be placed over several floors from top to bottom as well as from bottom to top with the associated cables and displayed correctly in the 3D view.
  • Generating a material list with the output type „3. Together + Ref. name” and activated „Additional parts” check box works correctly for the discipline EI.

CE module (Cabinet Engineering)

  • If you activate the Use parent check box for a CE element in the properties dialog under Cabinet part, the coordinates of the CE element are correctly adjusted to the specified reference point of the parent element.
  • CE pages that contain cabinet elements with cutouts are imported correctly.

v6.6.1.21

Data lansarii: 2020-11-16

SUITE X PLUS SP1

  • Clientii care au licente Suite Compact au acum posibilitatea de a folosi manager-ul de articole. In plus, functia “Editare Contact Comb” a fost modificata astfel incat sa se poata prelua inclusiv contactele din articolul respectiv
  • Cand se exporta proiectul in PDF, tot folderul de documente sau o singura pagina, se pot crea fisiere PDF individuale in toate limbile disponibile intr-un singur pas. In meniul de export a fost adaugat campul “PDF multilingual…”. Aceasta functionalitate este disponibila doar pentru utilizatorii cu un contract valabil de mentenanta
  • Din fila “Help | Delete empty containers” se pot sterge toate containerele expirate, goale sau imprumutate (pentru licentele Network).
  • In Plugin Manager s-a adaugat noul plugin pentru punctele de date BKS_15
  • Cand se foloseste pluginul BKS_13 pentru punctele de date, identificatorii de structura sunt preluati corect
  • Variabilele de cale pot fi folosite acum la generarea listelor, planurilor, salvarea proiectelor, dar si cand se exporta in PDF/DXF/DWG/graphics si exportarea catre interfetele CadCabel, Komax si Steinhauer.
  • Exista posibilitatea de a alege ce sectiuni sau foldere din document apar in cuprinsul PDF-ului doar folosind numele, numele si descrierea sau numele si comentariul, la momentul in care se face exportul,
  • S-au imbunatatit actualizarea punctelor de date dupa modificari aduse acestora in baza de date sau in pluginul punctelor de date.
  • S-a imbunatatit lucrul cu simbolurile cablurilor folosite atat in EI cat si in BA, in mai multe situatii.
  • O structura noua “Graphics and text are always in the foreground” a fost adaugata in fila “Tools | Settings (options) | Cabinet”. Daca este activa, pozele si textele inserate in paginile tabloului sunt plasate automat in prim plan. Daca, casuta este dezactivata, imaginile si textele pot fi plasate acum in spate, bazat pe setarile acestora din fereastra de proprietati din “View | Display sequence | Back”.
  • S-a adaugat butonul “Parts from connection attributes” in fereastra “Generate material list” cu scopul de a se vizualiza articolele atributelor de conexiune.
  • Folosind importul de planificare complet al clemelor Phoenix PROJECT, se ia in considerare corect decalajul de montare pentru dispunerea clemelor pe sina.
  • Exportul de planificare complet al clemelor Phoenix PROJECT a fost imbunatatit pentru clemele multi-nivel, accesoriile clemelor, jumpere si plug-inuri de jumpere.
  • Exportul complet de marcare Phoenix PROJECT a fost imbunatatit in ceea ce priveste referintele, elementele PLC, clemele, cablurile si firele.
  • Pentru interfata “Siemens TIA-Portal“ (din “Interface | Siemens | SPS CAEX”), a fost adaugat in PLC Manager noul tab “Variable table” (Tag Table). Acesta contine numele, tipul de date, adresarea si comentariile canalelor din modulul PLC
  • Extensia interfetei Siemens TIA: in PLC Manager si in fereastra de proprietati a elementului PLC parinte, elementul parinte poate fi definit ca si CPU bifand casuta respectiva. Se permite un singur CPU per modul.
  • Pentru exportul elementelor PLC folosind interfata Siemens TIA, tipul de date poate fi definit pentru fiecare canal in PLC Manager folosind campul “Data type”, de exemplu Bool (standard), Byte, Int, Real, etc. In timpul procesului de import, tipul de date setat se citeste din fisierul AML apoi se salveaza.
  • S-au adus cateva imbunatatiri si corecturi la interfata sistemului PRO FILE PLM. Atricolele care au primit un id de articol din PRO.FILE in WSCAD pot fi deschise direct din baza de date WSCAD in PRO.FILE. In plus, se poate schimba versiunea verificandu-se si statusul.
  • Cand se importa un fisier in format csv in baza de date pentru articole, caracterele speciale precum umlauturile pot fi folosite. Fisierul csv trebuie salvat in format UFT-8.
  • Datele de logare la serverul proxy sunt vizibile encriptat doar in fisierul app.wscfg.
  • Cand se deschide wscaduniverse.com din Suite, butonul “Import” este din nou vizibil in pagina de rezultatele cautarii.
  • Optiunea de actualizare (Update Dialog) accesibila din “Help | Internet Update” a fost complet reproiectata.
  • A fost imbunatatita navigarea intre ferestrele de proprietati utilizant tasta TAB.
  • Vederea in 3D a paginii unui plan de instalatii functioneaza acum corect.
  • Valorile introduse in variabilele din Project Wizard in “Mounting location”, “Plant”, “Installation site” si “Functional assignment” sunt proiectate corect in planurile generate.
  • Daca WSCAD Suite este deschis pe un ecran secundar, maximizat, aceasta pozitie ramane fixata chiar daca software-ul se restarteaza.
  • La generarea listelor si tabelelor se completeaza corect campurile “Section with structure identifier…”
  • In tabelul de conexiuni, conexiunile pot fi vizualizate continuu folosind mai multe coloane distribuite una langa alta per foaie.
  • Crearea de noi componente in Material Explorer functioneaza corect.
  • Un sir de cleme virtual definit in Terminal Manager poate fi pozitionat corect folosind Material Explorer.
  • Crearea unui proiect nou folosind template-ul “20. Sections with 4 aspects…” functineaza corect.
  • Dupa importul clemelor multi-nivel din “Import external material data” al ferestrei Material Explorer, clemele sunt grupate si sortate corect in Material Explorer.
  • Identificatorii de structura ale elementelor dintr-un macro plasat sunt afisati in ferestele de proprietati ale simbolurilor si in functiile de manager asociate.
  • Schimbare numelui de referinta, textul functional al unui cablu virtual functioneaza corect.
  • Daca functia de auto-numerotare (din “Tools | Numbering | Reference”) nu returneaza secventa de cabluri a simbolurilor din BA, se poate rezolva din “Tools | Check | Clean up file” inaintea efectuarii procesului de numerotare.
  • Stergerea numelui firelor din “Tools | Wire names | Remove wire names” functioneaza corect.
  • Cand se copiaza punctele de masura, acum se pot schimba numerele unice de identificare pentru noile puncte de masura.
  • Toate articolele aditionale ale unui contactor sunt acum vizibile in lista de materiale.
  • Textele atributelor de conexiune (wire color, wire cross-section, wire type, etc.) pot fi mutate/rotite/modificate separat
  • Informatiile de rutare, de exemplu lungimea, sectiunea, culoarea sunt afisate corect in diagrama de rutare.
  • Daca bobinele cu linii de actiune mecanica verticala sunt plasate una langa alta, la aceeasi inaltime, toate liniile de actiune sunt vizibile.
  • In fereastra “Create Project” butonul “Template” este presetat ca si structura de crearea a unui proiect nou. Daca se copiaza un proiect, butonul “Project” este presetat.
  • Setarea pentru redirectionarea automata a usilor poate fi modificata din “Tools | Settings (options) | Installation”.
  • Crearea de conexiuni pentru canalele virtuale ale PLC-urilor din PLC Manager functioneaza corect.
  • Cand se insereaza elemente in pagina tabloului folosind Material Explorer, dimensiunile pot fi specificate corect in fereastra “Enter dimensions”. Se poate folosi din nou functionalitatea “Draw manually”.
  • Daca se dezactiveaza casuta “Part data from database” cand se genereaza lista de materiale, aceste informatii nu se completeaza in lista.
  • Daca se modifica ordinea structurii proiectului cand se creaza un proiect nou (de exemplu din ==A1=B1++C1+D1 in ++C1+D1==A1=B1), denumirile de referinta ale simbolurilor plasate se atribuie in aceeasi ordine.
  • Dupa inserarea unui macro, informatiile articolului sunt transferate corect catre atributele de conexiune.
  • In lista de materiale, numele compoentelor pentru atricolele aditionale atribuite contactoarelor din Contactor Manager sunt afisate corect.
  • Liniile de conexiune medii pot fi aliniate corect cu liniile de grid folosind comanda din meniul contextual “Align to grid”. Liniile raman conectate la simboluri.
  • Cand se plaseaza un elment PLC child, textul canalului de adresare este aliniat corect.
  • Cand se activeaza casuta “Show pin texts” din “Tools | Settings (options) | Cabinet” numarul si numele pinilor se afiseaza la dimensiunea corecta.
  • Variantii de rotire au fost modificati in Symbol Editor si sunt plasati corect din Material Explorer.
  • Exportul paginilor din tablou in JPG grafic a fost imbunatatit. Textele din campurile cartusului sunt afisate corect.
  • Daca se activeaza casuta “New page for every structure identifier” cand se genereaza o lista de referinte, se genereaza o noua pagina pentru fiecare identificator de structura, altfel, doar liniile goale se insereaza intre identificatorii de structura.
  • Funcitoneaza corect importul de fisiere externe pentru rutare automata (accesibil din “Tools | Cabinet | Import external wiring”).
  • Cand se deschide fereastra “Macro variables” pentru un macro variant inserat in Project Wizard, baza de date a articolelor poate fi accesata corect din “Open part database” button.
  • Elementele din Distribution and Circuit Manager pot fi mutate folosind drag&drop – astfel se sorteaza elementele plasate la acelasi nivel.
  • In fereastra “Change part” din Part management, se atribuie corect modificarile aduse in campul “Part”.
  • Cand se sterg elemente din paginile EI care acopera partial cartusul, cartusul ramane in forma corecta.
  • Comentariile si descrierile unei structuri pot fi facute acum vizibile sau invizibile corect.
  • Se poate atribui un macro unui atricol din baza de date in campul “Symbol Cabinet”. Daca simbolul caruia i-a fost atribuit este plasat din Material Explorer, macro-ul este afisat corect.
  • Tipul de numerotare “Name sheet #1” setat in “Tools | Settings (options) | Numbering | Reference” se aplica, corect cand se creaza cabluri noi din Cable Manager.
  • Daca, casuta “Use external connection file” este activata din “Tools | Settings (options) | Cabinet | Routing”, si fisierul de rutare extern “ExtWiring.xlsx” se regaseste in folderul WSCAD “Externals”, acesta se va citi corect in momentul rutarii.
  • Elementele fara conexiune sunt afisate in tabelul de referinta (de exemplu un element PLC parinte cu pini virtuali de alimentare)
  • Dupa ce se insereaza elementul copil, referinta se pozitioneaza corect in campul respectiv al elementului parinte.
  • Se pot atribui culori corect pinilor clemelor din Terminal Manager folosing fereastra “Terminal Pin Color Configuration”
  • Daca mai multe canale (sau neinserate) sunt selectate in PLC Manager si se insereaza impreuna ca si elemente PLC in schema, toate aceste elemente apar in tabelul de referinta.
  • Se poate folosi cursorul in modul “Object (se poate seta din “Tools | Settings (options) | View | Cursor”).